Hello, welcome to Shenzhen Taigang Machinery Co., Ltd.!
Business:0769-81698040 13509666635 Technical Support:13509650331
2013-10-01 00:00:00
Click:
Centrifugal Compressor Maintenance Guide
Quarterly maintenance content :
1 Check the instrument air filters:
> Drain cleaning
> Replace the filter element
(2) low drainage control gas supply pipelines .
3 Check the trap .
> Apart Cleaning
> If necessary, replace
4 motor bearing grease into
> Shutdown , use the manual zerk
> Note grease type and quantity .
5 Visually inspect the air intake filter core .
> Clean and replace if necessary
6 Check the lubricator wick .
> Check whether the deformation of the old slug
> If necessary, replace
> Reinstallation attention to the U-tube fuel
7 lubricator core long-term use , no need to be changed frequently
8 Check the control cabinet
> Clean the cooling fan and filter
> Make sure no loose vibration transmitter connector
> Make sure that all terminal connections without loosening
Back to top
Half-yearly maintenance content :
1 lubricated air compressor coupling, visual inspection of the dry type couplings.
2 Check the exhaust check valves
3 Replace the oil filter
4 air cooler do hydrostatic pressure test, record the water pressure , the pressure of time and CTD.
5 Replace the motor ( self- lubricated ) Lubricants
6 air compressor lubricants sampling, analytical oil .
7 according to the operating manual compressor control system requires calibration .
8 Checksum inlet valve and bypass valve .
9 Repeat quarterly maintenance content .
Back to top
Annual maintenance content :
1 according to the compressor motor operating manual required to check
(2) Visually inspect the coupling, re- examination of lubrication , replacement of worn parts.
3 Rotate the large gear , large gear feeling self-lubricating bearings for wear.
4 Check and clean suction strainer .
5 Check the oil cooler pipe , if necessary, clean the cooling water channel .
6 Check the oil cooler internal corrosion ( zinc ) coating , if necessary, redo .
7 Check the intake valve .
8 Check the bypass valve .
9 Check the exhaust check valve .
10 oil change (TECHTROL GOLD exception )