Regenerative dryers common troubleshooting guide
1 Symptom : dew point temperature
· Purification flow is too low
· Import pressure is low
· Excessive moisture content
· Import temperature
· Import volume is too low
· Desiccant by oil pollution
· Regeneration temperature is too low
· Dew point indicator is incorrect
Back to top
2 Symptom : regeneration temperature is too low ( generally should be 250 ° F or 121 ° C)
· Thermostat faulty or set too low
· Renewable flow is too low
· Regeneration tower is too high backpressure
· Heater Damage
· Contactor failure
· Power Problems
· Heating time is too short
Back to top
3 Symptom : regeneration tower rushed back pressure is too high
· Muffler clogged
· Check valve leakage ( see note point 2 )
· Renewable too much traffic
· Renewable exhaust duct obstruction
· Valve diaphragm ruptures
Back to top
4 Symptom : too much traffic through the muffler
· Check Valve Leak
· Inlet valve is not switched
· Renewable exhaust valve remains open
· Boost valve can not be closed
· Valve diaphragm ruptures
Back to top
5 Symptom : No gas through a drying machine
· Pipe network pressure is too low, two inlet valve closed
Low pressure protection switch is set too high
Back to top
6 Symptom : set the alarm for tower
· Inlet valve does not switch
· Turn the timer or micro switch failure
· Pilot pressure is not normal
· Cylinder leakage or blockage
Back to top
7 Symptom : Tower not pressurized
· Renewable exhaust valve remains open
· Boost valve failure
· Valve diaphragm ruptures
Back to top
8 Symptom : Dryer too much pressure drop
· Support desiccant filter clogging
· Over Flow
· Recycling stream is too high
· Regeneration valve to remain open
· Step shutters remain open
Back to top
9 Symptom : drying machine can purify
· Orifice clogged
· Regeneration valve can not be opened
· Regeneration valve closes
REPRO -way valve plug
Back to top
10 Symptom : Moisture inside the silicone color red indicator
· Moisture indicator in front of the intake valve closes
• All valves work properly
Back to top
11 Symptom : tower can not be fully pressurized
· Import pressure is low
· Purification pressure is too low
· Boost time is too short