Micro-oil screw compressor Common Troubleshooting Guide
1 , failure phenomenon: the unit high exhaust temperature (over 100 ° C)
· Unit coolant level is too low ( should be from the oil sight glass that can be seen , but not more than half ) ;
· Oil cooler dirty ;
· Oil filter core blockage ;
· Thermostatic valve failure ( bad elements ) ;
· Off the oil solenoid valve without electricity or coil damage ;
· Off the oil solenoid valve diaphragm rupture or aging ;
· Fan motor failure ;
· Cooling fan is damaged ;
· Exhaust pipe is not blocked or exhaust resistance ( back pressure ) large ;
· Ambient temperature exceeds the specified range (38 ° C or 46 ° C);
· Temperature sensor fault (Intellisys control unit ) ;
· Pressure gauge is faulty ( relay control unit ) .
Back to top
2 , fault phenomenon: large or compressed air oil fuel unit volume
· Cooling dose too much, the correct location should be observed when the unit load , then the oil level should be no more than half ;
· Return pipe blockage ;
· Return pipe installation ( with the distance from the bottom of the oil separator element ) does not meet the requirements ;
· Unit is running the exhaust pressure is too low ;
· Oil separation core rupture ;
· Separation cylinder internal partitions damaged ;
· Unit oil leaks ;
· Coolant deterioration or extended use .
Back to top
3 , fault phenomenon: low pressure unit
· Set output volume is greater than the actual gas consumption ;
· Bleeder valve failure ( can not turn off when loaded ) ;
· Intake valve failure ;
· Hydraulic cylinder failure ;
· Load solenoid valve (1SV) failure
· Minimum pressure valve stuck ;
· User pipeline leaks ;
· Pressure set too low ;
· Pressure sensor fault (Intellisys control unit ) ;
· Pressure gauge fault ( relay control unit ) ;
· Pressure switch failure ( relay control unit ) ;
· Pressure sensor or pressure gauge input hose leak ;
Back to top
4 , fault phenomenon: high discharge pressure unit
· Intake valve failure ;
· Hydraulic cylinder failure ;
· Load solenoid valve (1SV) fault ;
· Pressure setting is too high ;
· Pressure sensor fault (Intellisys control unit ) ;
· Pressure gauge fault ( relay control unit ) ;
· Pressure switch failure ( relay control unit ) .
Back to top
5 , fault phenomenon: large current unit
· Voltage is too low ;
· Loose wiring ;
· Unit pressure exceeds the rated pressure ;
· Oil separation core plug ;
· Contactor failure ;
· Host failure ;
· Main motor failure ;
Back to top
6 Symptom : The unit does not start
· Fuse bad ;
· Temperature switch is broken ;
· Wiring release ;
· Main motor thermal relay ;
· Fan motor thermal relay ;
· Transformers bad ;
· Intellisys no power input (Intellisys control unit ) ;
· If the fault persists (Intellisys control unit ) ;
· Intellisys controller failure .
Back to top
7 , fault phenomenon: the unit starts when the current large or trip
· User air switch problem ;
· Input voltage is too low ;
* Star - delta conversion interval is too short ( should be 10 ~ 12 seconds ) ;
· Hydraulic cylinder failure ( no reset ) ;
· Intake valve failure ( opening is too large or stuck ) ;
· Loose wiring ;
· Host failure ;
· Main motor failure ;
· 1TR bad time relay ( relay control unit ) .
Back to top
8 , failure phenomenon : Fan motor overload
· Fan deformation ;
· Fan motor failure ;
· Fan motor thermal relay fault ( aging ) ;
· Loose wiring ;
· Cooler clogged ;
· Exhaust resistance is large .